50/60Hz TRANSFORMERS | HIGH FREQUENCY TRANSFORMERS | INDUCTORS | OTHER INDUCTIVE COMPONENTS


itacoil transformers
Main transformers  
EI series safety transformers
Measurement transformers  
50/60Hz Current transformers CT
SBT Current transformers
SDL Split Core current transf.
SHL AC-DC current sensor
SVL Voltage transformers
NEW PRODUCTS  
new products, transformers, inductors, coils
 
For the detailed features please see the catalogue
inherently short-circuit proof
Main transformers 50/60 Hz
power transformers STD EI30 Series
EI Standard Series
 
This category contains the following standard series:
EI series safety Main transformers
UI series safety Main transformers - low profile

Features

Safety isolating transformers according to CEI EN61558-1(CEI 96-3) and CEI EN 61558-2-6 (CEI 96-7)
Primary and secondary windings in separate sections
Encapsulation in epoxy resin
Hot-dip tin coated phosphor bronze pins
Pin size: Max diameter = 0,90mm , Minimum length = 4mm
Primary side marking
5KV Primary to Secondary dielectric strength
100% tested
RoHS compliant
Custom versions on request also with ENEC IMQ (1VA)
   

size(mm)

a max

b max

h max

x typ.

y typ.

1 sec. layout

2 sec. layout

download

1005S - 0,65VA

32,4

27,7

15,2

5,0

20,0

drawing 1

drawing 2

file 3D .stp

1010S - 1VA

32,6

28,0

22,1

5,0

20,0

drawing 1

drawing 2

file 3D .stp

1011S - 1,5VA

32,6

28,0

22,1

5,0

20,0

drawing 1

drawing 2

file 3D .stp

1012S - 1,5VA

32,6

28,0

24,3

5,0

20,0

drawing 1

drawing 2

file 3D .stp

1013S - 1,9VA

32,6

28,0

24,3

5,0

20,0

drawing 1

drawing 2

file 3D .stp

1015S - 2VA

32,6

28,0

27,4

5,0

20,0

drawing 1

drawing 2

file 3D .stp

1019S - 2,3VA

33,1

28,6

29,7

5,0

20,0

drawing 1

drawing 2

file 3D .stp

1207S - 2,3VA

41,4

34,9

21,7

5,0

25,0

disegno 1

disegno 2

file 3D .stp

1018S - 3VA

33,1

28,6

29,7

5,0

20,0

drawing 1

drawing 2

file 3D .stp

1024S - 3VA

32,7

27,8

34,4

5,0

20,0

drawing 1

drawing 2

file 3D .stp

1023S - 4VA

32,7

27,8

34,4

5,0

20,0

drawing 1

drawing 2

file 3D .stp

1214S - 4,1VA

41,5

35,5

27,5

5,0

25,0

drawing 1

drawing 2

file 3D .stp

1220S - 6VA

41,7

35,3

34,6

5,0

25,0

drawing 1

drawing 2

file 3D .stp

1414S - 5,5VA

45,4

38,3

31,9

5,0

25,0

drawing 3

drawing 4

file 3D .stp

1616S - 11VA

51,2

43,0

37,8

5,0

27,5

drawing 3

drawing 4

file 3D .stp

1620S - 15VA

51,4

43,3

41,3

5,0

27,5

drawing 3

drawing 4

file 3D .stp

1625S - 18,5VA

50,6

42,7

45,7

5,0

27,5

drawing 3

drawing 4

file 3D .stp



pin side view

Layout Layout Layout Layout Standard EI
drawing 1 drawing 2 drawing 3 drawing 4 dimension


The transformers defined in the catalogue as “safety transformers” meet the harmonized European standards EN61558-1 (CEI 96-3) and EN 61558-2-6 (CEI196-7). They are manufactured with high quality material and with manufacturing processes developed in a 20 year old experience; this is guarantee of very high quality and reliability. The tests of the functional parameters and of the dielectric strength between primary and secondary windings, carried out on every single item, practically eliminate any rejects on production lines. The position of the primary and secondary windings in separated chambers and the encapsulation in epoxy resin make these transformers particularly safe and strong, both mechanically and electrically. They moreover withstand atmospheric pollution such as dust, humidity, and so on. The use of pins made of tin-plated phosphor bronze make them very resistant and very easy to weld.
The meaning of the different types of overload and short circuit protection is in compliance with the above mentioned standards and can be explained as follows:
- Inherently short-circuit proof: the transformer which undergoes a short circuit under the conditions foreseen by the standard does not reach, in the short period, temperatures which may be dangerous for the material it is made of.
- Output fuses: in order to prevent overload or short circuit from reaching dangerous temperatures, the transformer has to be protected by means of a fuse delayed by the value indicated on each secondary output; for transformers up to 30VA the fuses must comply with the standard CEI EN 60127.2.3 (e.g. series ST523 Omega); for transformers with higher power the fuse must comply with the standard CEI EN 60127.2.6 (e.g. series VT521 Omega). As in the EN61558 the primary voltage is subject to tolerances +/-10%; the rated output of the transformer shall be selected accordingly.